Your browser doesn't support javascript.
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
1.
Braz J Infect Dis ; 25(2): 101543, 2021.
Article in English | MEDLINE | ID: covidwho-1084394

ABSTRACT

In the pandemic, rapid and accurate detection of SARS-CoV-2 is crucial in controlling the outbreak. Recent studies have shown a high detection rate using saliva/oral fluids as specimens for laboratory detection of the virus. We intended to evaluate the test performance of the Xpert Xpress SARS-CoV-2 cartridge assay in comparison to a conventional qRT-PCR testing, using saliva as biological specimen. Forty saliva samples from symptomatic participants were collected. Conventional qRT-PCR was performed for amplification of E and RdRp genes and the Xpert Xpress SARS-CoV-2 assay amplified E and N2 genes. In the conventional assay, the median cycle threshold value of the E gene was 34.9, and of the RdRp gene was 38.3. In the Xpert Xpress assay, the median cycle threshold value of the E gene was 29.7, and of the N2 gene was 31.6. These results can allow a broaden use of molecular tests for management of COVID-19 pandemic, especially in resources-limited settings.


Subject(s)
COVID-19 , SARS-CoV-2 , COVID-19 Testing , Clinical Laboratory Techniques , Humans , Nasopharynx , Pandemics , Polymerase Chain Reaction , Saliva , Sensitivity and Specificity , Specimen Handling
2.
Braz. j. infect. dis ; 24(5):422-427, 2020.
Article in English | LILACS (Americas) | ID: grc-745422

ABSTRACT

Background Severe Acute Respiratory Syndrome Coronavirus 2 (SARS-CoV-2) is the cause of Coronavirus Disease 2019 (COVID-19). Although Real Time Reverse Transcription Polymerase Chain Reaction (qRT-PCR) of respiratory specimens is the gold standard test for detection of SARS-CoV-2 infection, collecting nasopharyngeal swabs causes discomfort to patients and may represent considerable risk for healthcare workers. The use of saliva as a diagnostic sample has several advantages. Objectives The aim of this study was to validate the use of saliva as a biological sample for diagnosis of COVID-19. Methods This study was conducted at Infectious Diseases Research Laboratory (LAPI), in Salvador, Brazil. Participants presenting with signs/symptoms suggesting SARS-CoV-2 infection underwent a nasopharyngeal swab (NPS) and/or oropharyngeal swab (OPS), and saliva collection. Saliva samples were diluted in PBS, followed by RNA isolation and RT-Real Time PCR for SARS-CoV-2. Results of conventional vs saliva samples testing were compared. Statistical analyses were performed using Statistical Package for the Social Sciences software (SPSS) version 18.0. Results One hundred fifty-five participants were recruited and samples pairs of NPS/OPS and saliva were collected. The sensitivity and specificity of RT-PCR using saliva samples were 94.4% (95% CI 86.4-97.8) and 97.62% (95% CI 91.7-99.3), respectively. There was an overall high agreement (96.1%) between the two tests. Conclusions Use of self-collected saliva samples is an easy, convenient, and low-cost alternative to conventional NP swab-based molecular tests. These results may allow a broader use of molecular tests for management of COVID19 pandemic, especially in resources-limited settings.

3.
Braz J Infect Dis ; 24(5): 422-427, 2020.
Article in English | MEDLINE | ID: covidwho-734982

ABSTRACT

BACKGROUND: Severe Acute Respiratory Syndrome Coronavirus 2 (SARS-CoV-2) is the cause of Coronavirus Disease 2019 (COVID-19). Although Real Time Reverse Transcription Polymerase Chain Reaction (qRT-PCR) of respiratory specimens is the gold standard test for detection of SARS-CoV-2 infection, collecting nasopharyngeal swabs causes discomfort to patients and may represent considerable risk for healthcare workers. The use of saliva as a diagnostic sample has several advantages. OBJECTIVES: The aim of this study was to validate the use of saliva as a biological sample for diagnosis of COVID-19. METHODS: This study was conducted at Infectious Diseases Research Laboratory (LAPI), in Salvador, Brazil. Participants presenting with signs/symptoms suggesting SARS-CoV-2 infection underwent a nasopharyngeal swab (NPS) and/or oropharyngeal swab (OPS), and saliva collection. Saliva samples were diluted in PBS, followed by RNA isolation and RT-Real Time PCR for SARS-CoV-2. Results of conventional vs saliva samples testing were compared. Statistical analyses were performed using Statistical Package for the Social Sciences software (SPSS) version 18.0. RESULTS: One hundred fifty-five participants were recruited and samples pairs of NPS/OPS and saliva were collected. The sensitivity and specificity of RT-PCR using saliva samples were 94.4% (95% CI 86.4-97.8) and 97.62% (95% CI 91.7-99.3), respectively. There was an overall high agreement (96.1%) between the two tests. CONCLUSIONS: Use of self-collected saliva samples is an easy, convenient, and low-cost alternative to conventional NP swab-based molecular tests. These results may allow a broader use of molecular tests for management of COVID19 pandemic, especially in resources-limited settings.


Subject(s)
Coronavirus Infections , Pandemics , Pneumonia, Viral , Betacoronavirus , Brazil , COVID-19 , Clinical Laboratory Techniques , Coronavirus Infections/epidemiology , Humans , Pneumonia, Viral/epidemiology , SARS-CoV-2 , Saliva
SELECTION OF CITATIONS
SEARCH DETAIL